Floor Coating

NR CRYSTAL(W) FAST Solvent Free Clear Epoxy

usage
Clear epoxy for concrete surfaces

This paint is a 2K non-solvent type epoxy clear paint composed mainly of non-solvent-based epoxy resin and modified amine resin. It is excellent in the hardness of dry film, adhesion, durability, chemical resistance and dust proofness. It has excellent smoothness and can form a beautiful appearance after painting. It is more effective if an interior design is applied before applying this paint.

specification

Paint type
Modified epoxy / Modified amine (2-Component)
Drying time
Drying time
Category 5℃ 20℃ 30℃
Set-to-touch 5 hours 2.5 hours 3 hours
Dry-through 18 hours 8 hours 10 hours
Pot life 20 minutes 10 minutes 5 minutes
Thinner
Not Applicable
Dilution ratio
▷No dilution ▷In case of high viscosity in the winter season, dilute within the volume ratio 1%
Specific gravity
Approx. 1.09
Theoretical Coverage
100 sq. ft./gal.
Solid volume ratio
100%
Color
Clear (Compounds)
Thickness of dried film
16mils
Mixing ratio
Base(A)/hardener(B)=2/1 (Volume ratio)
Gloss
Glossy
Shelf life
12 months
Packaging unit
Available as customized

how to use

Surface treatment
1. Cure concrete for at least 28 days at a temperature of 21℃ and a relative humidity of 50%.
2. Completely remove the oil, moisture, sand, dust, laitance and other foreign matter from the surface and maintain surface smoothness.
Coating method
1. Reinforce cracks, crevices, and joints between walls and floors with an epoxy putty after primer.
2. Apply smoothly using sawtooth scraper, rubber scraper, pitchfork, square towel, etc.
3. Care should be taken since problems may occur such as cratering upon thin coating. (2mm or less - 1 time)
Appropriate construction specifications
▷Primer : Epoxy primer
▷Mid coat : Epoxy/polyurea basecoat
▷Top coat : Urethane/polyaspartic(optional)
Coating conditions
1. Atmosphere Temperature: 5~35℃, Surface Temperature: 40℃ or below, Relative Humidity: 80% or less, Moisture content in the concrete: 6% or less
2. Due to the nature of epoxy lining transparent paint, a color difference may be shown over time if the coating surface is a bright color.
3. The degree of occurrence of yellowing varies depending on the long-term exposure to sunlight or the use time of indoor lighting, etc.
4. The use of a thinner more than the recommended amount causes a further delay in drying,
5. Pot life will be shorten when mixing mass volumes of A+B as it generates heat reaction.
So, we recommend you follow the below procedures when applying bucket packing of it. (15 gallon)
a. Stir Part A and Part B separately before mixing together.
b. Apply on the surface to be coated as soon as PART A + PART B are mixed uniformly together because of short pot life.